Elation PARAGON S handleiding

58 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 6 van 58
6
IP54 RATED
The International Protection (IP) rating system is commonly expressed as “IP” (Ingress Protection)
followed by two numbers (i.e. IP54), where the numbers de󱁕ne the degree of protection. The 󱁕rst digit
(Foreign Bodies Protection) indicates the extent of protection against particles entering the 󱁕xture,
and the second digit (Water Protection) indicates the extent of protection against water entering the
󱁕xture. An IP54 rated lighting 󱁕xture is designed and tested to protect against dust in󱁕ltrating in a
quantity large enough to interfere with operation (5), and splashing water from any direction (4).
This rating means that the 󱁕xture can withstand rainwater, splashes, condensation, etc., but CANNOT
withstand high-pressure water jets. This 󱁕xture is designed for use in any weather conditions, but
cannot withstand fountains, waterfalls, showers, or other conditions that can generate larger amounts
of water. Do not immerse the 󱁕xture in water, and immediately disconnect power to the 󱁕xture in the
event of extreme situations such as 󱁖oods.
NOTE: THIS FIXTURE IS INTENDED FOR TEMPORARY OUTDOOR USE ONLY! Permanent installion in
an outdoor location may accelerate aging, potentially compromising the device’s IP54 rating and posing
potential safety hazards and damage risks. Do not use this 󱁕xture in permanent outdoor applications.
Do not install this 󱁕xture near seawater, swimming pools, or any environment with a high
concentration of salt or chlorine in the air. Do not use this 󱁕xture in any environment with extremely
cold or freezing temperatures.
NOTE: NOT ALL FEATURES LISTED ARE AVAILABLE ON ALL FIXTURES; THE FOLLOWING INSTRUCTIONS
MAY NOT APPLY. CONTACT SUPPORT FOR ADDITIONAL DETAILS.
Exterior Maintenance: Inspect the exterior every 30 days. Ensure the unit is powered o󱁔/disconnected.
Examine the chassis for contaminants and clean optics and chassis as necessary. Schedule maintenance
based on 󱁕ndings, taking into account the exterior’s exposure to the elements. Maintenance is crucial
even when luminaires are not in use due to their exterior placement. Regularly inspect power and
data lines for contaminants or corrosion. Clean thoroughly and/or replace connectors if corrosion/
contaminants are present.
Interior Maintenance: Inspect the interior every 30-days. The unit must be powered o󱁔/disconnected.
Examine zoom/focus mechanism, clean optics, and lubricate linear bearings (Krytox oil) as needed
inspect belts for wear
Manually rotate all rotating e󱁔ect wheels and note any resistance.
Check remaining rotating belts for wear.
Inspect and clean fans as required, checking rotation and connections
Examine the CMY module, manually moving 󱁖ags and checking for resistance
Clean guide rods if needed and apply a thin layer of grease (moly lube).
Clean the interior with low-volume compressed air and clean optics before reassembling head covers.
Although the base and yoke have limited moving parts, the pan and tilt belt should also be inspected
for wear.
There is no speci󱁕c time frame regarding the routine replacement of parts such as belts/stepper motors,
PCBs, or LEDs. These items should only be replaced on an as needed bases, except for cooling fans, which
should be replaced once the luminaries reach 10,000-hours. This is a prophylactic measure intended
to keep the unit running as cool as possible, insuring proper function of all internal components. A
complete service breakdown is available, please contact service@elationlighting.com for any needed