Elation OPTI TRI WHITE II handleiding

24 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 19 van 24
www.elationlighting.com
19 OPTI TRI WHITE IIUser Manual Ver. 1
DMX CHANNEL FUNCTIONS AND VALUES
ELATION© OPTI TRI WHITE II™
DMX Channel Values / Functions (8 DMX Channels)
Specifications are subject to change without any prior written notice.
MODE /
CHANNEL
VALUE FUNCTION
4 CH 8 CH
1 1
COOL WHITE*
*COOL WHITE Control Disabled when fixture is in 8 CH Mode
and CH 4 Color Macros are being used.
0-255
COOL WHITE (0-100%)
2 2
WARM WHITE*
*WARM WHITE Control Disabled when fixture is in 8 CH Mode
and CH 4 Color Macros are being used.
0-255
WARM WHITE (0-100%)
3 3
AMBER*
*AMBER Control Disabled when fixture is in 8 CH Mode
and CH 4 Color Macros are being used.
0-256
AMBER (0-100%)
4
COLOR TEMPERATURE MACROS
0-18 OFF
19-37 7500K
38-56
7000K
57-75
6500K
76-94
6000K
95-113
5500K
114-132
5100K
133-151
4700K
152-170
4300K
171-189
3900K
190-208
3500K
209-227
3100K
228-246
2700K
247-255
2300K
5
STROBE / SPEED*
*SPEED Control ONLY available when fixture is in 8 CH Mode
and CH 6 DMX Value is (129-255)
0-255 *SPEED Control SLOW to FAST
6
STROBE / FADE MODES
0-128
NO Function
129-159
STROBE
160-191
COLOR FADE
192-223
Random STROBE
224-255
Random PULSE STROBE
7
DIMMER INTENSITY
0-255 Intensity 0 to 100%
4 8
DIMMING CURVE MODES
0-19 STANDARD
20-39 STAGE
40-59 TV
60-79 ARCHITECTURAL
80-99 THEATRE
100-255 Default to Unit Setting

Bekijk gratis de handleiding van Elation OPTI TRI WHITE II, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkElation
ModelOPTI TRI WHITE II
CategorieVerlichting
TaalNederlands
Grootte3810 MB