Elation Focus Spot 250R handleiding

48 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 40 van 48
Focus Spot 250R™
©Elation Professional® 40 Focus Spot 250R™
05Er - Color-wheel error:
The color wheel is not located in the default position after start-up or after a reset
command.
This message will appear after a fixture reset if the color wheel’s magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
06Er - Rotating gobo-wheel error:
The gobo-wheel is not located in the default position after start-up or after a reset
command.
This message will appear after a fixture reset if the gobo wheel’s magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
07Er - Rotating gobo indexing error:
The gobo is not located in the default position after start-up or after a reset command.
This message will appear after a fixture reset if the gobo positioning magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).

Bekijk gratis de handleiding van Elation Focus Spot 250R, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkElation
ModelFocus Spot 250R
CategorieVerlichting
TaalNederlands
Grootte4720 MB