28 EMOTION™ User Manual Ver. 1
NETWORK SYNCHRONIZATION REQUIREMENTS
In order for Network Synchronization to function properly, there are a few
requirements that must be adhered to in the set-up of the fixtures:
All of the servers must be linked on an Ethernet network through the graphics server
port. This network must be configured on a DHCP network and the router must have
sufficient bandwidth to handle all connected fixtures. Low cost 10/100 wireless
routers may not work properly; higher quality 100/1000 routers are generally
preferred.
The Fixture ID for each fixture on the network must be unique. The Fixture ID is used to
assign the master and slave servers. Having multiple media servers with the same
Fixture ID will cause Network Synchronization to fail. Fixture ID is set via the CMA.
All video content to be used in a Synchronization scenario MUST adhere to the
encoding requirements for encoding custom content. If the content is not encoded
correctly Network Synchronization will not function. Specifically all image
information must be present at all frame locations. Highly compressed video does
not contain all image information in every frame, but only the changes from a
key-frame previously encountered in playback.
NETWORK SYNCHRONIZATION CAPABILITIES
The system is designed to help keep the movie playback time relatively in sync, as
perceived. The system is not designed to frame lock or gen-lock, these features will
not be supported in the Emotion fixture. Synchronization is used between multiple
servers for Collage applications, or other perceived playback applications.
NETWORK - ENABLE
To enable network sync, all fixtures must be on an Ethernet network, have an IP
assigned by a DHCP, and have a unique ID number. Sync is activated by changing
the Sync Control channel from zero to the fixture ID that is meant to be the sync
target. For example, 4 fixtures connected have fixture ID’s of 11, 12, 13, 14. The sync
master is meant to be the 4
th
fixture, which in this example would be 14. Setting the
sync value of all fixtures to 14 will tell the fixtures to listen to the 4
th
fixture. Note that
there is no issue setting the master to sync to its self. By selecting all fixtures in the
sync group, and setting them to the same value eases programming and minimizes
mistakes.
FIXTURE CONTROL, PROJECTOR CONTROL
The fixture control channel is used to set various functions and features of the
EMOTION fixture. When there is not a specific command needed, the control
channel must be set to Idle or Safe (Channel 7, Value of 0). Please note, leaving a
control channel active can impact performance, as the projector can be
constantly responding to command. For example, if the projector is commanded to
flip, there will be the initial change, and every second after; the projector will
attempt to change again. Please leave the control channel at Idle when not
intending to make a change.