9.1.3 <DISP> - Menu Display Settings
This function allows the internal programs to run in either stand-alone or master/salve
DMX chain. In “Alone” mode
“VALU” - Display the DMX 512 value of each channel
This function will electronically display the current DMX value for any channel that is
currently being adjusted. The display will automatically detail the changing DMX
values as they are received from the controller. This function is “off” by default.
“FLIP” – This function will flip the display readout by a 180˚ allowing for better
visualization when the fixture is mounted in an inverted position.
D ON” The display is designed to turn off during normal operation to avoid
excessive light in situations that require an extremely dark environment. This
function will adjust the time delay the fixture will remain on before it turns off. This
function is disabled as default.
9.2 “SET” – Fixture Personality Settings:
These functions set specific running modes and operating parameters.
<CHAN> DMX Mode settings
This function allows the fixture to run in different DMX channel modes. The five modes
are available; 3 channel, 4 channel, 6 channel, 12 channel and 15 channel. See “DMX
Traits” beginning on page 27 for a detailed explanation of the different DMX modes.
<FAIL> DMX Fault Protection
This function dictates how the fixture will operate in the event DMX signal is suddenly
lost while operating in DMX mode. The three fail safe modes are; 1) “OFF” which will
blackout all light output. 2) “HOLD,” which will hold the last DMX command, or 3 “AUTO,”
which will put the fixture in sound-active mode.