Elation Design Spot LED handleiding
Handleiding
Je bekijkt pagina 40 van 52

Design Spot LED™
©Elation Professional® 40 Design Spot LED™
05Er - Color-wheel error:
The color wheel is not located in the default position after start-up or after a reset command.
This message will appear after a fixture reset if the color wheel’s magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
06Er - Rotating gobo-wheel error:
The gobo-wheel is not located in the default position after start-up or after a reset command.
This message will appear after a fixture reset if the gobo wheel’s magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
07Er - Rotating gobo indexing error:
The gobo is not located in the default position after start-up or after a reset command. This
message will appear after a fixture reset if the gobo positioning magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
08Er - Fix Gobo-wheel error
This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive
circuit on the main PCB). The fix gobo wheel is not located in the default position after the
reset.
10Er - Focus-error
This message will appear after the reset of the fixture and if the magnetic indexingcircuit
malfunctions (sensor failed or magnet missing) or the stepping-motor isdefective (or its
driver circuit on the main PCB). The focus motor is not located in the defaultposition after the
reset.
13Er - Iris-error
This message will appear after the reset of the fixture and if the magnetic indexingcircuit
malfunctions (sensor failed or magnet missing) or the stepping-motor isdefective (or its
driver circuit on the main PCB). The Iris motor is not located in the default position after the
reset.
Bekijk gratis de handleiding van Elation Design Spot LED, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Elation |
| Model | Design Spot LED |
| Categorie | Verlichting |
| Taal | Nederlands |
| Grootte | 5181 MB |






