Elation Design Spot 250 Pro handleiding

56 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 47 van 56
Design Spot 250 Pro™
©Elation Professional® 47 Design Spot 250 Pro
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
driver circuit on the main PCB). The focus motor is not located in the default position after
the reset.
13Er - Iris-error
This message will appear after the reset of the fixture and if the magnetic indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
driver circuit on the main PCB). The Iris motor is not located in the default position after the
reset.

Bekijk gratis de handleiding van Elation Design Spot 250 Pro, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkElation
ModelDesign Spot 250 Pro
CategorieVerlichting
TaalNederlands
Grootte5733 MB