Maintenance
56
Non-lubrication drain plug
4.5 Nm
Lubrication drain plug
3.4 Nm
11. Put back the tank, install and tighten the
hydraulic oil tank of the fasteners. Torque
according to the following requirement:
Torque to specification.
Non-lubrication hydraulic tank
fastener
4.0 Nm
Lubrication hydraulic tank fastener
2.9 Nm
12. Link hydraulic pump inlet pipe into the tank.
13. Link hydraulic pump return pipe with the
return filter.
14. Fill the tank with hydraulic oil until the fluid
is at Max. Indicator, Do not over fill.
15. Activate the pump to fill the hydraulic
system with oil and bleed the system of air.
Component damage
Component damage hazard. The pump can
be damaged if operated without oil. Be careful
not to empty the hydraulic tank while in the
process of filling the hydraulic system. Do not
allow the pump to cavitate.