Malfunction remedy
Malfunction
Cause
Remedy
The unit does not start up
No mains voltage
Check the mains voltage.
Impeller unit blocked
Clean
Water flow insufficient
Regulator closed too far
Adjust regulator
Filter housing or impeller unit soiled
Clean
Impeller unit worn
Replace impeller unit
Insufficient filtering perfor-
mance
Foam filter clogged
Clean
Foam filter worn
Replace
The activated carbon is exhausted.
Replace the activated carbon.
Technical data
EDEN FIN
25
50
Rated voltage of pump
AC V
230
230
Mains frequency of pump
Hz
50
50
Pump power consumption
W
5
5
Suitable for aquariums up to
l
25
50
Max. pump capacity
l/h
240
240
Max. pump head
m
0.4
0.4
Filter volume
l
0.1
0.2
Dimensions
Length
mm
43
85
Width
mm
47
47
Height
mm
120
120
Mains connection cable length
m
1.5
1.5
Permissible water temperature
°C
+4 ... +35
+4 ... +35
Weight
kg
0.2
0.3