5.3. Installing an External Power Supply
In case of not having a PoE type power received in the WP22DN panel directly from the
connection port of the network switch to which it is connected, it is possible to power
the panel through an optional external power supply, model WP-PSU or WP24-PSU,
with stripped wires connected to the Euroblock + and - terminals shown in 5.1.
Mounting the unit.
WP-PSU power supply
6. POWER UP AND MANAGEMENT FROM DANTE CONTROLLER
SOFTWARE
6.1 WP22DN Power Up
When the unit is connected to the DANTE/AES67 network and supplied with PoE or
external DC supply, the front panel LED indicators will show the following information:
POWER LED: will light up in green meanwhile the unit is powered
DANTE LED: will light with the following coded information:
RED (fixed): during the boot up process
AMBER (fixed): during the PTP (Precision Time Protocol) network time
synchronization
GREEN (fixed): when the unit has been set up as a D DANTE/AES67 Slave
GREEN (blinking): when the unit has been set up as a DANTE/AES67 Master