7.2 ASCII Commands
ASCII command control is supported via the SERVICE port. When connected to a PC using
a micro-USB cable, a serial command tool can be used to send ASCII commands. The
following tables provide a summary of all supported commands, including their functions,
expected feedback, and default settings.
The communication settings must be configured as follows:
• Baud rate: 115200 (default)
• Data bits: 8bit
• Stop bits: 1
• Check bit: 0
Each command consists of a structure with specific delimiters and parameters, as described
below:
• [y] - Parameter 1
• [z] - Parameter 2
• ! - Delimiter (all commands must end with '!')
The command set includes functions to control power, retrieve device information, configure
video and audio outputs, manage EDID settings, and more. The following tables provide a
comprehensive list of available commands grouped by functionality.
EXAMPLE OF USE:
To enable HDCP on CAT output 1: < s cat [y] hdcp [z]! >
• y=1 defines the CAT output port 1
• z=1 enables HDCP
The command to use is: < s cat 1 hdcp 1! >
This command activates HDCP on CAT output 1.
To disable HDCP for all CAT outputs, the user should use: < s cat 0 hdcp 0! >
Power
Command Code
Variable
Description
s power [z]!
z=0~1
• 0 = power off
• 1 = power on
Power on/off the device
r power!
-
Get current power state
s reboot!
-
Reboot the device