MIMO88SG / MIMO1212SG (SINGLE) DIGITAL MATRIX
IMPORTANT NOTE: The communication must be started with the client sending the first message SYSTEM CONNECT or SYSTEM CONNECT
ONCE to the EclerNet device. Otherwise, the commands from the client to the EclerNet device will be ignored. See TP-NET PROTOCOL
INTRODUCTION chapter for additional information.
TYPE PARAM1 PARAM2 PARAM3 PARAM4 DESCRIPTION
SYSTEM
CONNECT
[MASTER]
[PINGPONG]
[ONCE]
MASTER: this parameter, applied in SYSTEM
CONNECT, is used to disconnect all clients
currently connected to the device, releasing all
open and not correctly closed connections,
opening a new connection. In this way we
guarantee that the client that has set the
MASTER option is the only one connected by
TP-NET to the device.
PINGPONG: this parameter can be used with
the MASTER parameter, the difference is that
this parameter performs a periodic check to
see if the communication is still open (PING
PONG) or if after 10 seconds with no
response, the communication has ended
(PING).
ONCE: this parameter is used to prevent the
device status dump.
DISCONNECT
Cancel subscriptions and terminates
communication
SUBSCRIPTION_RATE
<Rate>
Alive message from device
PING
Alive message from device
PONG
Alive ACK message from client