Ecler MIMO88 handleiding
Handleiding
Je bekijkt pagina 22 van 30

22
• Automatically: in case the initial message was SYSTEM CONNECT PINGPONG
and the client didn’t get any SYSTEM PONG message in a period longer than 10
seconds (presuming a communication breakdown)
The SET messages don’t have an automatic acknowledgement with a DATA message
sent from the EclerNet device after it has processed the SET command. The client must
update the values itself and must send the needed GET message if it requires
confirmation from the device.
NOTES:
• The numerical values are always integer numbers without +, –, comma or dot
symbols.
• [PINGPONG] is an optional parameter used to configure the device-client
communication with a periodical check, to see whether the client or the device have
terminated it. When configured this way, the device sends a SYSTEM PING once
per second, and the client must answer with a SYSTEM PONG message. If anyone
doesn’t get these messages along a 10 seconds period, the communication will be
considered terminated.
• [ONCE] is an optional parameter used to start the device-client communication
without a full data dump process (usually a huge list of parameters & values).
• <Input Channel> & <Output Channel> are numerical values that identify an input
or output channel of the EclerNet device.
It can be within a [1..8] range for MIMO88 single units (8x8 matrix masters), and
[1..16] for MIMO88 couples configured as 16x16 matrix masters.
• <Preset Number> is a numerical value that identifies one available Preset stored in
the EclerNet device’s memory.
For the MIMO series it can be within the [1..99] range.
• <Level>, <Pre Vumeter Level> y <Post Vumeter Level> are numerical values in the
[0..100] range that define values in a scale equivalent to [-inf..0] dB
• <GPI> & <GPO> are numerical values within the [1..8] range for the MIMO88
configured as 8x8 matrix masters (single units), and [1..16] for MIMO88 couples
configured as 16x16 matrix masters.
• <GPI Value> is a numerical value within the [0..100] range that indicates the value
of an analogue GPI input. For a digital input only 0 or 100 are the possible values.
• <GPO Value> is a numerical value within the [0..1] range: it can only be 0 or 1
(opened or closed GPO).
• <Rate> is a numerical value within the [1..10] range that sets the VU-meter refresh
rate, or the number of times the vumeters’ values are sent per second (by default =
3).
Bekijk gratis de handleiding van Ecler MIMO88, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Ecler |
| Model | MIMO88 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 3164 MB |







