MAINTENANCE AND CARE (CONTINUED)
68
Remove side service cover
Remove air lter cover clips
The side service cover is located on the handle side of the
generator. Remove the 2 bolts around the service cover with
an 8 mm socket wrench and remove the side service cover.
The air lter cover is located toward the bottom of the
engine. Remove both air lter cover clips.
1.
2.
3.
Remove air lter cover
Remove the air lter cover and sponge-like element from the
casing.
Routine maintenance of the air cleaner helps maintain proper
airow to the carburetor. Check that the air cleaner is free of
excessive dirt after every use.
CAUTION: Improper maintenance may cause
less air to enter the engine or dirty air to enter
the engine causing overheating and engine
wear.
Cleaning the Air Filter