Durkopp Adler D888 handleiding

264 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 147 van 264
Programming Commander DELTA
Operating Instructions D888 e-con - 00.0 - 12/2023 145
5.9.6 Setting the Seam Begin/Segment Begin
parameters
There are various options for setting the Seam Begin/Segment
Begin parameters. The following table lists all possible options.
Settings that are more complex and therefore require further
explanation are described in more detail after the table.
Icon Parameter Settings
Parameters Seam Begin
Scan Mode
(Access only after activation in the
machine configuration)
Value range
Read & Compare/Read & Store/Off
Seam begin bartack parameters
Bartack at seam begin Value range
On/Off
Number of stitches backwards Value range
01 50 [stitches]
Number of stitches forward Value range
01 50 [stitches]
Number of bartack sections
A bartack consists of several sections. If the
sewing direction is changed, a new section
is started. The number of sections in a
bartack can be set here.
Value range
01–99
Stop-Time for direction change
The waiting time at the turning points
(e.g. for a change of sewing direction)
is set at this point. A short waiting time in
milliseconds should ensure consistent seam
quality (ornamental-stitch bartack).
Value range
0000 1000 [ms]
RFID

Bekijk gratis de handleiding van Durkopp Adler D888, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkDurkopp Adler
ModelD888
CategorieNaaimachine
TaalNederlands
Grootte27738 MB