Programming Commander DELTA
Operating Instructions D867 e-con - 00.0 - 06/2023 117
5.8.5 Setting the Segment parameters
There are various options for setting the parameters in the segment.
The following table lists all possible options.
Settings that are more complex and therefore require further
explanation are described in more detail after the table.
Icon Parameter Setting
Seam Parameter
Stitch length Value range
00.0 - 12.0 [mm]
(depending on the sewing equipment
and the subclass)
Needle thread tension Value range
01 - 99
Sewing foot pressure Value range
01 - 20
Sewing foot stroke Value range
1.0 9.0 [mm]
Max. Speed
It is possible to reduce the maximum
sewing speed at this point. The maxi-
mum sewing speed can be set in the
software at the Technician level.
Value range
0050 3800 [rpm]
(depending on subclass)
Sewing foot lift at stop Value range
On/Off
Height of sewing foot lift at
stop
Value range
00 20 [mm]
(depending on subclass)