Programming Commander DELTA
Operating Instructions D867 e-con - 00.0 - 06/2023 113
5.8.3.4 Function modules
This parameter provides virtual switches that can be assigned
customer-specific functions. They can be used when customer-
specific applications require a signal from the control of the machine.
This parameter cannot be used unless the function modules have
been assigned to a physical output at the Technician level. This
requires that the parameter Module management be configured
at the Technician level; for more details, refer to the explanation
in the Service Instructions.
It is possible for each function module to place one function tile
(stored) on the main screen ( p. 89).
5.8.3.5 Setting the Outputs (Output) parameter
This parameter provides virtual outputs that can be assigned cus-
tomer-specific functions. They can be used when customer-specific
applications require a signal from the control of the machine.
This parameter cannot be used unless the virtual outputs have
been assigned to a physical output at the Technician level. This
requires that the parameter Module management be configured
at the Technician level; for more details, refer to the explanation
in the Service Instructions.
Menu item Setting 1 Setting 2
Function modules 1 - 8 Value range
Material thickness/input
Material thickness
Only visible in the mode
Material thickness.
The function module
becomes active starting with
the entered limit.
Value range
00–10[rpm]
(depending on subclass)