Durkopp Adler D867 e-con handleiding
Handleiding
Je bekijkt pagina 113 van 286

Programming Commander DELTA
Operating Instructions D867 e-con - 00.0 - 06/2023 111
Setting options Needle thread tension
Menu item Setting 1 Setting 2
Linear
absolute
Needle thread tension
Value range
00–99
Maximum needle thread
tension reached at the
upper speed limit.
Min.
Sewing speed
Value range
0000 – 4000 [rpm]
(depending on subclass)
Speed at which
the increase in needle
thread tension should start.
Max.
Sewing speed
Value range
0000 – 4000 [rpm]
(depending on subclass)
Speed up to which the
increase in needle thread
tension should occur.
Linear
with
offset
Offset
Value range
-99–99
Difference up to maximum
needle thread tension
reached at the upper speed
limit.
Min.
Sewing speed
Value range
0000 – 4000 [rpm]
(depending on subclass)
Speed at which the
increase in needle thread
tension should start.
Max.
Sewing speed
Value range
0000 – 4000 [rpm]
(depending on subclass)
Speed up to which the
increase in needle thread
tension should occur.
2. Value
On/Off
Min.
Sewing speed
Value range
0000 – 4000 [rpm]
(depending on subclass)
Speed from which the
2
nd
needle thread tension
should be used.
2. Value
On
Min.
Sewing speed
Value range
0000 – 4000 [rpm]
(depending on subclass)
Speed from which the
2
nd
needle thread tension
should be used.
Bekijk gratis de handleiding van Durkopp Adler D867 e-con, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Durkopp Adler |
| Model | D867 e-con |
| Categorie | Naaimachine |
| Taal | Nederlands |
| Grootte | 32197 MB |