CODE PROBLEM SOLUTION
FAULT
ICON
ACTIVATED
ALARM
05
DC
undervoltage
rotection
Press
DC
button
Beep
three
times
07
DC
overcurrent
protection
1
Press
DC
button
13
USB
output
undervoltage
Press
DC
button
15
USBl
Output
overload Press
DC
button
16
USB2
Output
overload Press
DC
button
17
USB3
Output
overload Press
DC
button
18
USB
total
output
overcurrent
Remove
the
device
connected
to
the
USB
port
and
the
G800
will
recover
19
Power delivery
port
output
protection
Remove
the
device
connected
to
the
USB
port
and
the
G800 will
recover
20
Power delivery 2
output
protection
Remove
the
device
connected
to
the
USB
port
and
the
G800 will
recover
36
AC120V
overcurrent
protection
Remove all
the
loads
connected
to
the
G800
and
press
the
AC120V
button
21
Low
battery
protection
Charge
the
G800 until
the
SOC
increases
above
5%
and
the
fault
will
clear
automatically
26 Fuse
protection
Remove
the
load
and
press
the
reset
breaker
button
27
Undervoltage
protection
Remove
the
load
and
charge
the
G800
and
it recovers
automatically
30
Low-temperature
discharge
protection
Remove
the
load
and
wait
for
the
G800
temperature
to
recover
32
Charge
low-temperature
protection
Wait
for
the
battery
temperature>?
degrees
C
and
the
G800 will recover
automatically