Draper 18070 handleiding

20 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 15 van 20
– 15 –
10. MAINTENANCE
10.1 DAILY CHECK-UP
Warning!
Check-up and cleaning must be done after stopping ‘combustion’ of the heater.
Check if fuel leaks from any place near the fuel tank.
Check if combustion chamber or heating tube is corroded and damaged.
If heat-reecting board is dusty, clean it.
Check if the heater makes soot from the exhaust pipe.
Burner is adjusted to be suitable for function of the heater. If there are no user serviceable parts on
this heater – all service functions must be carried out by a suitably qualied professional.
Warning!
Cleaning the heater should be done after unplugging the cable and when it is completely cooled
down. It should be cleaned with a damp cloth and then dried. NEVER pour water on or use spray
detergents or cleaners on or around this heater.
10.2 REGULAR INSPECTION
Regular Inspection
Combustion furnace and heating tube (heat exchanger): once a year, check for soot and then
clean it as required.
Combustion furnace and reection board: once a year, check for corrosion and pollution and then
clean it (when it is corroded too much, exchange it).
Fuel lter (inside the tank): once a year, check for pollition with naked eyes and then exchange it.

Bekijk gratis de handleiding van Draper 18070, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkDraper
Model18070
CategorieHeater
TaalNederlands
Grootte1615 MB