After raising the support to the highest height, press and hold it for 5 seconds, the
screen displays "rES" for reset, and when the screen displays the height 160 again,
The reset succeeded. Procedure
Long press the button to make the support continue to rise. The support stops rising
when the button is released, or stops when the maximum height (160cm) is reached.
Long press the button to keep the bracket falling, stop the bracket falling when the button
is released, or stop the bracket when the minimum height (120cm) is reached.
Adjust the stand to your preferred height, then long press the or or button until the
LED shows H1 or H2 or H3 and flashes for about 3 seconds, then the LED shows the height
you have set, then the height memory setting is complete.
1 2 3
E20
E02
E32
E31
E10
Hot
Overvoltage warning: The input voltage is too high. If the AC adapter is correct, power off the device,
remove the controller cable, wait 5 minutes, plug in the cable, plug in the power, and reset the device.
Press any key once to wake up the display.
Overheat protection: When the motor operates continuously, it will stop running to prevent damage caused
by overheating. Wait for a period of time (15-20minutes) before making any further height adjustments.
Overload protection: If the support load exceeds the maximum load, power off, remove some heavy objects
from the table, and then plug in the power supply again.
Operation status warning: The support stops moving when vibration, shock, or tilt is detected. If the
detection result is incorrect, reset it and use it again.
Sensor malfunction warning: Motor safety sensor cannot be detected. Please power off, unplug the cables
of the controller, wait for 5 minutes, then plug in the cables and connect the power again, and perform
RES settings again.
Undervoltage Protection: Input voltage too low. If the correct AC adapter is being used, please power off,
unplug the cables of the controller, wait for 5 minutes, then plug in the cables and connect the power again,
and perform RES settings again.
Cable Disconnection Warning: Please power off, unplug the cables of the controller, wait for 5 minutes,
then plug in the cables and connect the power again, and perform RES settings again.
Reset
Controller Introduction
Protection Mode Error Codes