INSTALLING HUMIDY SYSTEM CONT.
INSTALL WATER HEATER ELEMENTS (18612-0367) USING THE NUTS SUPPLIED WITH THE
ELEMENTS.
o MAKE SURE GASKET IS IN THE INTERIOR SIDE OF THE MOUNT
INSTALL TWO WATER PAN MOUNTS (50039148) USING (4) 1/4-20 SS PAN HEAD SCREWS
(53-0840) EACH
NOTE: USE LONG PHILILPS SCREW DRIVER TO ACCESS ALL FOUR MOUNT
HOLES
INSTALL HUMIDITY SENSOR (66-1146) (CIRCLED IN RED), FEED WIRE THROUGH
GROMET
o ROUTE HUMIDITY SENSOR LEAD AND ATTACH THE LEAD PORT LABELED "TH
SENSOR",AS SHOWN
SLIDE PANS SLIDE OUT ON PAN MOUNTS AND INSTALL PANS (50039148).
WHEN PANS ARE IN POSITION, MOVE SLIDES BACK
MAKE SURE FIBER
WASHERS ARE ON
THE INTERIOR
SIDE OF THE
MOUNT
MAKE SURE
STEEL WASHERS
ARE ON THE
EXTERIOR SIDE
OF THE MOUNT
RUN HUMIDITY
SENSOR LEAD
THROUGH THIS
GROMMET
OPENING