A 15
WATLOW PROGRAMMING
The Watlow temperature control can record 12 different menus. It must be programmed before use.
It will save its programs in case of power failure.
Each menu includes 3 "STEPS" and each step includes :
Symbol
temperature SP
time t
"EVENT" E (steam 0001, auto steam 0100, buzzer 0010 or
no event 0000)
To access the programming mode :
Press both arrows simultaneously for 5 seconds. Both lights light up to show that the
programming mode is working.
Unlock the read only mode (if necessary), press 12 and "CLOCK", LOC appears. Use the arrows
to get 0 and press "CLOCK" again. (To put back on read only mode, you have to have 1 before
pressing on "CLOCK".)
EXAMPLE 1 (preheat program)
- For menu #1, we will program it so that we have a preheat time of 20 minutes at 400°F followed
by a 15 seconds buzzer.
Step #1
Press both arrows simultaneously for 5 seconds. Both lights light up to show that the
programming mode is working.
Select the program number (Ex : #1)
Suggested values
SP1 appears.
Use the arrows to adjust to the desired temperature (400°F)
Press on the number of the menu to confirm (ex. # 1)
t1 appears
Use the arrows to select the desired timing (20:00)
Press on the number of the menu to confirm (ex. # 1)