Problem Possible cause Suggested remedy
Fault: AC High Voltage The supply voltage is too high.
1. Verify the voltage is correct at the power source.
2. If the problem persists, contact a qualified service techni-
cian.
Fault: DC Low Voltage The battery capacity is reduced.
1. Charge or replace the battery bank.
2. If the problem persists, contact a qualified service techni-
cian.
Fault: DC High Voltage The supply voltage is too high.
1. Verify the voltage is correct at the power source.
2. If the problem persists, contact a qualified service techni-
cian.
An electrical part has failed.
Contact a qualified service technician.
Fault: Communication Loss
Electrical noise interference.
Ensure communication cables and connectors are not in close
proximity to power cables or large electrical equipment.
Fault: Overcurrent Alarm An electrical part has failed.
Contact a qualified service technician.
Airflow is restricted due an object in the airflow path.
Remove the obstruction from the heatsink cooling airflow
path.
Fault: High VFD Temperature
The cooling fan is not operating correctly.
Contact a qualified service technician.
Fault: Fan Fault An electrical part has failed.
Contact a qualified service technician.
Fault: Duplicate Zone Instance More than one unit in a network has been assigned to the
same zone ID.
Check the zone assignments on all units in the network to en-
sure each unit has a unique zone ID.
Fault: Low Refrigerant A mechanical interface has failed and lost refrigerant.
Contact a qualified service technician.