DMT Alpha Series A1.9i handleiding
Handleiding
Je bekijkt pagina 33 van 40

7. Troubleshooting
This troubleshooting guide contains solutions to problems which can be carried out by an ordinary person. The
device does not contain user-serviceable parts.
Unauthorized modifications to the device will render the warranty void. Such modifications may result in injuries
and material damage.
Refer servicing to instructed or skilled persons. Contact your Highlite International dealer in case the solution is
not described in the table.
Problem Probable cause(s) • Solution•
The device does not function (LEDS
on the backside are OFF). See LED
Indicator Status (see 8.5.3. LED
Indicator Status on page 35)
No power to the
device
• Make sure that the device is connected to•
power supply and the cables are connect
Internal fuse is blown
• Disconnect the device and contact your•
Highlite International dealer
The device does not function (LEDS
on the backside are ON). See LED
Indicator Status (see 8.5.3. LED
Indicator Status on page 35)
The device is not
connected correctly
• Make sure that the signal cables are•
connected correctly
• Replace the signal cables•
The device cannot
output the received
signal
• Make sure the connected devices•
(NovaStar processor) work correctly
• Make sure the connected devices•
(processor) are compatible with NovaStar
The device responds erratically
The settings of the
device are changed
• Reset the device’s parameters to the•
default factory settings. See control modes
(see 6.2. Control Modes on page 31)
One device in the setup does not
respond to data control
The signal cables to
the control box are not
connected
• Connect the signal cables•
The control box is
defective
• Try using another control box. Contact•
your Highlite International dealer
Individual LED pixels on the LED
screen do not work or flicker
Individual LED pixels on
the LED screen module
are damaged
• Disconnect the device and replace the•
LED screen module (see 8.4. Replacing a
LED Screen Module on page 34). Contact
your Highlite International dealer for a
spare LED screen module
The driver of one of
the LED screen
modules is defective
• Disconnect the device and replace the•
LED screen module (see 8.4. Replacing a
LED Screen Module on page 34). Contact
your Highlite International dealer for a
spare LED screen module
32
c
Product code: 101812
Alpha Series A1.9i
Bekijk gratis de handleiding van DMT Alpha Series A1.9i, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | DMT |
| Model | Alpha Series A1.9i |
| Categorie | Verlichting |
| Taal | Nederlands |
| Grootte | 9579 MB |