ATTENTION!
In order to avoid a hazard due to inadvertent
resetting of the thermal cutout, this appliance
must not be supplied through an external
switching device, such as a timer or
connected to a circuit that is regularly
switched on and off by the utility.
ATTENTION!
Connection only to fixed installed cables! The
hardwired electrical installation must be
provided with a disconnect device with a
contact grap of at least 3 mm at each pole
(e.g. automatic circuit breaker)!
ACHTUNG!
The device must be earthed!
2 Energy saving functions
2.1 Dual circuit heating element
The Dimplex RCE radiant heat convector has a con-
vection heating element and a radiant heating system.
This combination enables just the radiant heating to be
used if the temperature difference is low. This mini-
mises the risk of overheating the room, which saves
energy.
2.2 "Open Window" function
If a window or a door is left open by mistake, the control
will detect the sudden temperature fluctuations and
switch to Standby mode. If the window or door is
closed, the device returns to normal mode. This func-
tion interrupts the heating operation to prevent heat
from escaping from the room in an uncontrolled man-
ner. This saves money and minimises energy con-
sumption.
2.3 Learning function
This function enables the heating device to be switched
on early to ensure that the desired temperature is
reached at the time specified in the program.
Example: A temperature of 21°C is set for mornings at
7 am in the time program. The heating device now de-
termines how long it takes to reach the desired temper-
ature at the specified time based on its "experience".
NOTENOTE
If the Anticipatory (ES) function is activated, the device
heats for the pre-set time to ensure that the room has
reached the required temperature at the right time.
Technical Device Description.
3 Technical device description
4 Assembly, installation, minimum clearance
The radiant heat heating device is designed for wall
mounting using the wall bracket provided. The device
may only be installed in upright position as shown in
Fig. 1 - 3.
Caution with inflammable objects. The minimum clear-
ances must be complied with. A distance of at least
500mm must be complied with on the front of the de-
vice.
Type
Output
radiant
heating
Output
convector
heating
Total
output
RCE 050 200 W 300 W 500 W
RCE 100 300 W 700 W 1000 W
RCE 150 300 W 1200 W 1500 W
RCE 200 350 W 1650 W 2000 W
Connection voltage 1/N/PE~230-240V, 50Hz
Temperature controller 7 - 32°C
Protection class Protective conductor con-
nection
Degree of protection IP24