With �ssue paper dipped in alcohol to clean the new
electrodes, then, install the electrodes into the original
electrodes seat posi�on.
4. Close the electrodes cover and �ghten the screws.
5. Close the windproof cover and power on the machine.
6. Take an electrode aging.
7. Run 3 �mes fiber fusion if current fusion parameter is
Auto mode otherwise run Arc Test or Arc Calibrate if
current fusion parameter is normal or calibrate
Note: The replacement of the electrodes should be gentle, so
as not to damage the machine or stabbed himself.
5.3. Electrode aging
The electrodes arc begins unstably when the external
environment such as the temperature and pressure changed
greatly especially moving the machine from low al�tude to
high al�tude. When happened, users should take an electrode
aging to stabilize the electrodes arc. The machine runs 5 �mes
of huge electrodes arc when the user selects the electrodes
aging and executes it.
Note: Please according prompts to operate, do not open the
cover while electrodes aging