DWL-5x000XY DATA SHEET
Byte [n] Command Descriptions
Byte [0] 0x71 To control box / From Sensor 1
Byte [1] 0x1B Single Axis Position / Calibration Mode
Byte [2] 0x17 Calibration Feedback : Idle
Byte [3] 0x1E Calibration Count : 30
Byte [4] 0x13 Dummy
Byte [5] 0x03 Calibration Step 3 Ready
Byte [6] 0x88 Dummy
Byte [7]~[9] 0xDD Fixed Dummy
Byte [10] 0x22 CRC16 High
Byte [11] 0x93 CRC16 Low
10. For DWL5000XY model, repeat step 3 to step 8. Please locate the sensor module in fol-
lowing positions (refer to Figure 45 to Figure 50) respectively.
11. For DWL5500XY & DWL5800XY model, please perform only 4 steps calibration as shown in
Figure 43, 44, 49, and 50.
12. Once the following response is received, the calibration process is completed.
>> (From control box): 0x71, 0x2B, 0x17, 0x1E, 0x13, 0x08, 0x88, 0xDD, 0xDD, 0xDD, 0x22, 0x93
The sensor module will automatically change to dual axis mode and broadcast dual
axis angle measurement (Please refer to 7.4.2 Dual Axis Mode) after the calibration pro-
cess is completed.
Figure 45. Tilt Sensor Module Position of Calibration Step 3
Figure 46. Tilt Sensor Module Position of Calibration Step 4