- 24 -
3.9 WIFI Connec�on
For the configura�on of Wi-Fi Plug, please refer to illustra�ons of the Wi-Fi Plug. The Wi-Fi Plug
is not a standard configura�on, it's op�onal.
3.8 Earth Connec�on(mandatory)
Ground cable shall be connected to ground plate on grid side, this prevents electric shock if the
original protec�ve conductor fails.
Warning:
Inverter has built-in leakage current detec�on circuit, The type A RCD can be
connected to the inverter for protec�on according to the local laws and regula�ons.
If an external leakage current protec�on device is connected, its opera�ng current
must be equal to 300 mA or higher, otherwise inverter may not work properly.
Earth connec�on (Copper wires) (bypass)
Earth connec�on (Copper wires)
Model
4kW
Wire Size
14AWG
Cable(mm )
2
1.5
Torque value(max)
1.2Nm
3kW 16AWG 1.0 1.2Nm
5/6kW 12AWG 2.5 1.2Nm
8kW 10AWG 4.0 1.2Nm
10/12kW 8AWG 6.0 1.2Nm
Model
3/4/5/6/8/10/12kW
Wire Size
6AWG
Cable(mm )
2
10
Torque value(max)
1.2Nm