Deye SUN-45K-G04P3-EU-AM4-LV handleiding

67 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 62 van 67
Error code Description Ongrid - Three Phase
F40 DC over current Hardly appear the code. Never ever happened so far.
F39
AC over current(one cycle)
1. Check AC current sensor and its circuit.
2. Restart the inverter, if the fault still exists, contact your
installer or Deye service.
F41
AC Line W,U over voltage
Check the AC voltage protection setting. And Check if the AC
cable is too thin.Check the voltage difference between LCD and
meter.
F55
DC busbar voltage is too high
1. Check PV voltage and Ubus voltage and its detection circuit.
If the PV input voltage exceeds the limit, please reduce the
number of solar panels in series.
2. For Ubus voltage, please check the LCD display.
F56
DC busbar voltage is too low
1. It tells the PV input voltage is low and it always happens in the
early morning.
2. Check PV voltage and Ubus voltage. When inverter is running,
then showing F56, maybe Loss of driver or need update
firmware.
3. Restart the inverter, if the fault still exists, contact your
installer or Deye service.
F43
AC Line V,W over voltage
Check the AC voltage protection setting.And Check if the AC
cable is too thin.Check the voltage difference between LCD and
meter.
F45
AC Line U,V over voltage
Check the AC voltage protection setting.And Check if the AC
cable is too thin.Check the voltage difference between LCD and
meter.
F42
AC Line W,U low voltage
Check the AC voltage protection setting. Check the voltage
difference between LCD and meter. Also need to check whether
AC cables are all firmly and correctly connected.
F44
AC Line V,W low voltage
Check the AC voltage protection setting. Check the voltage
difference between LCD and meter. Also need to check whether
AC cables are all firmly and correctly connected.
F46 AC Line U,V low voltage Check the AC voltage protection setting.
F47 AC Over frequency Check the frequency protection setting.
F57 AC reverse irrigation AC reverse irrigation.
F58 AC grid U over current Hardly appear the code. Never ever happened so far.
F48 AC lower frequency Check the frequency protection setting.
F49
U phase grid current DC
component over current
Hardly appear the code. Never ever happened so far.
F50
V phase grid current DC
component over current
Hardly appear the code. Never ever happened so far.
F51
W phase grid current DC
component over current
Hardly appear the code. Never ever happened so far.
F52
AC inductor A, phase current
DC current high
Hardly appear the code. Never ever happened so far.
F53
AC inductor B, phase current
DC current high
Hardly appear the code. Never ever happened so far.
F54
AC inductor C, phase current
DC current high
Hardly appear the code. Never ever happened so far.
- 59 -

Bekijk gratis de handleiding van Deye SUN-45K-G04P3-EU-AM4-LV, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkDeye
ModelSUN-45K-G04P3-EU-AM4-LV
CategorieNiet gecategoriseerd
TaalNederlands
Grootte6779 MB