DeWalt DWV015 handleiding

32 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 9 van 32
7
ENGLISH
Filter
Filter Care
If you experience a loss of suction performance due to a clogged
filter, turn the unit off, close the twist‑lock hose inlet
10
with the
inlet plug
19
, start the unit, and wait 15 seconds until you hear
the clicking sound of the filter cleaning two times. If the suction
performance is still not sufficient the filters must be changed.
The HEPA filters
9
included with this vacuum are long‑
life filters. To be effective in minimizing dust recirculation,
especially in lead paint (EPA RRP Rule) applications, the filters
MUST be installed correctly and in goodcondition. Check the
filter conditions before you use the tool.
To Remove Filters (Fig. I)
1. Turn on/off tool control switch
15
to the OFF position
( ) and unplug cord fromoutlet.
2. Release canister latches
4
and remove vacuum head
3
from canister. Place vacuum head on a level surface
upsidedown.
3. Turn each filter counterclockwise by gripping it on the
plastic end cover as shown, and carefully remove from
head, ensuring debris does not fall into mountinghole.
NOTE: Use care to not damage filtermaterial.
4. Inspect filters for wear, tears or otherdamage.
NOTE: If there is any doubt on the condition of the filters
they MUST be replaced. DO NOT continue use if filters
aredamaged.
MAINTENANCE
WARNING: To reduce the risk of serious personal
injury, turn unit off and disconnect it from
power source before making any adjustments or
removing/installing attachments or accessories.
An accidental start‑up can causeinjury.
Your DeWALT power tool has been designed to operate
over a long period of time with a minimum of maintenance.
Continuous satisfactory operation depends upon proper tool
care and regularcleaning.
To Shut Down (Fig.A)
1. Turn on/off tool control switch
15
to the OFF
position( ).
2. Unplug theunit.
Telescoping Handle (Fig.H)
Press telescoping handle release button
17
to raise and
lower the telescoping handle
16
.
To Convert Back to Dry VacuumOperation
1. Empty canister, refer to To Empty Canisterinstructions.
2. Place canister upside‑down position until dry. DO NOT
use wet canister for dry pickup.
3. Place vacuum head
3
on a level surface untildry.
4. Reinstall filters when vacuum head is dry. Refer to Filters
underMaintenance.
5. When canister is dry place the vacuum head onto the
canister and secure it by closing the canister latches
4
.
To Empty Canister (Fig.G)
The ball float valve
22
will block air to the motor when the
canister is full and the sound of the motor will change at
once. When the motor has a high‑pitched sound and air/
water flow stops, empty thecanister.
1. Turn off vacuum and unplug cord fromoutlet.
2. Unlatch canister latches
4
and remove vacuum head
3
.
3. Empty contents of canister
6
into a suitable container
ordrain.
Wet Pickup Applications (Fig.G)
WARNING: DO NOT connect power tools to outlet
when using the vacuum for wet pickup.
WARNING: Plug vacuum into GFCI protected outlet
when using the vacuum for wet pickup.
NOTICE: DO NOT remove ball float
22
as doing so
will cause damage to the vacuum. The ball float keeps
water from entering themotor.
Before using the vacuum for wet pickup:
Ensure the canister is empty and free of
excessivedust.
Remove HEPA filters
9
.
Plug vacuum into a GFCI protectedoutlet.
Automatic Filter Cleaning System
This vacuum has a highly effective filter cleaning system
which minimizes filter clogging. Every 30 seconds, one of the
two filters gets automatically cleaned. The cleaning process
alternates between the filters and continues through the life
of theunit.
NOTE: After starting the vacuum, both filters get cleaned
within the first 15 seconds.
NOTE: It is normal to hear a clicking sound during
thisprocess.
NOTE: After many hours of operation the automatic filter
cleaning system may not be effective. When this happens
the filters will need to be cleaned or replaced. Refer to Filter
underMaintenance.
off automatically with the powertool.
NOTE: The vacuum cleaner starts automatically within
0.5seconds and continues to run for 7 seconds after the
power tool has been turnedoff. Afterrun can vary when
used with a power generator
4. To switch back to manual mode, turn the on/off tool
control switch to the ON position (
). In manual mode
the tool and the vacuum are turned on and off
independent of eachother.
5. Choose the correct power tool adaptor
21
to fit the
power tool connection on the tool to be used. Refer to
Accessories under Maintenance. Attach power tool
adaptor to the powertool.
6. Attach the anti‑static suction hose
7
to the power
tooladaptor.

Bekijk gratis de handleiding van DeWalt DWV015, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkDeWalt
ModelDWV015
CategorieNiet gecategoriseerd
TaalNederlands
Grootte5359 MB