Handleiding
Je bekijkt pagina 22 van 56

2222
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS Air necessary for combustion [m
3
/h]
Auxiliary (A) 2,00
Semi-rapid (SR) 3,50
Rapid (R) 6,00
Double-ring compact (DCC) 8,00
BURNERS
Nominal
Power
[Hs - kW]
Reduced
Power
[Hs - kW]
LPG
G30 28-30 mbar
G31 37 mbar
Natural Gas
G20 20 mbar
Ø injector
[1/100 mm]
Ø injector
[1/100mm]
Auxiliary (A) 1,00 0,40 50 72 (X)
Semi-rapid (SR) 1,75 0,45 65 97 (Z)
Rapid (R) 3,00 0,75 85 128 (H3)
Double-ring
compact (DCC)
4,00 1,50 100 150 (H3)
LUBRICATION OF THE GAS TAPS
• In case of difculty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation maintenance of the appliance must be fullled
with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
TABLE FOR THE CHOICE OF THE INJECTORS
GB
Cat: II 2H3+
IE