Installation to Natural Gas
Installation to Natural Gas must conform to the Code of Practice, etc.
The supply pressure for Natural Gas is 20 mbar.
The installation must conform to the relevant British/European Standards.
Installation to LP Gas
When operating on Butane gas a supply pressure of 28-30 mbar is required.
When using Propane gas a supply pressure of 37 mbar is required.
The installation must conform to the relevant British/European Standards.
Warning: Only a suitably qualied and registered installer, also with technical knowledge of electricity should install
the appliance.
He should observe the Regulations and Codes of Practice governing such installation of gas appliances.
Note: It is recommended that the gas connection to the appliance is installed with a exible hose connecting tube
made to BS669 or EN 14800.
Notes:
• Flexible hoses can be used where the sited ambient temperature of the hose does not exceed 70 °C.
These hoses must be manufactured in accordance with BS669 part 1 or EN 14800 and be of the correct
construction for the type of gas being used.
• Gas hoses designed for natural gas MUST NOT be used for supplying LPG gas (LPG gas hoses can be
identied by a either a red band or stripe on the rubber outer coating of the hose).
The hose should not be crushed or trapped or be in contact with sharp or abrasive edges.
IMPORTANT! It is the responsibility of the gas installer to ensure that the product is fully tested and
commisioned in accordance with current regulations to ensure there are no gas escapes.
Gas connection (gs. 2.2a, 2,2b, 2.3, 2.4)
• The gas supply must use the gas inlet pipe which is located at the left hand side at the rear of the appliance.
• IMPORTANT NOTE: Before connecting the appliance to the gas mains t the female connector (supplied with
the appliance in a separate kit) to the inlet pipe using the bre washer supplied.
• IMPORTANT: Check the correct positioning of the connector as per pictures and always operate using
two suitable spanners.
• The hose should not be crushed or trapped or be in contact with sharp or abrasive edges. It should also not be
subjected to corrosion by acidic cleansing agents.
The hose should also be connected in such a way that it does not touch the oor and must hang in a natural
loop between the appliance and the bayonet tting.
• The pipe does not cross the rear panel of the cooker. In case of crossing the back panel, ensure the pipe is
positioned close to the bottom part of the appliance.
• To avoid damage to the appliance gas rail inlet pipe the ttings should be tightened using two suitable spanners.
Gas inlet pipe
Connector
Fig. 2.2a