16 Part Number: 9295093 07/23
Installation Section 2
Model BTU/Hour
Capacity
Heat of
Rejection
R290 Charge
STD4460NP 1704 576 75g
STD4460NP-8
2973 1645 72g
STD4460NP-12
STD4460NP-12M
STD4460NP-18M
STD4464NP-8
2973 1664 72g
STD4464NP-12
STD4464NP-12M
STD4464NP-18M
STD4472NP 1704 700 75g
STD4472NP-12
2973 2042 72gSTD4472NP-18M
STD4472NP-24M
Refrigerated Front Breathers w/ Doors & Raised Rail Prep Table
4448RP 1756 1084 60g
4472RP 2899 1636 72g
4496RP 2899 2093 72g
Refrigerated Front Breathers w/ Drawers & Raised Rail Prep Table
D4448RP 1756 1084 60g
D4472RP 2899 1636 72g
D4496RP 2899 2093 72g
Model BTU/Hour
Capacity
Heat of
Rejection
R290 Charge
Freezer Front Breathers with Doors
4527NP
1445
425
105g
4532NP
476
4548NP
686
4560NP
1879 827 150g
Freezer Front Breathers with Drawers
D4527NP
1445
471
105g
D4532NP
532
D4560NP
1879 937 150g
Freezer Front Breathers with Doors & 4” S/S Backsplash
ST4527NP
1445
425
105g
ST4532NP
476
ST4548NP
686
ST4560NP
1315 827 150g
Freezer Front Breathers with Drawers & 4” S/S Backsplash
STD4527NP
1445
471
105g
STD4532NP
532
STD4560NP
1879 937 150g
Level & Stable
After the cabinet has been placed in the desired location,
cabinets with legs must be leveled. Level units from front to
back and from side to side. Leveling will insure proper door
operation and removal of condensate. It is very important
that all legs are properly adjusted to keep the cabinet level,
evenly distribute the weight and to make sure the unit will
not rock, lean or be unstable.
Cabinets with casters must have the caster brake set so the
cabinet cannot move.
Leg & Caster Installation
DANGER
Legs or casters must be installed and the legs or casters
must be screwed in completely to prevent bending. When
casters are installed the mass of this unit will allow it to
move uncontrolled on an inclined surface. These units
must be tethered/secured to comply with all applicable
codes.
n
Warning
The unit must be installed in a stable condition with
the front wheels locked. Locking the front casters after
installation is the owners and operators responsibility.
n
Warning
Use a jack to lift the refrigeration unit off the ground
just far enough to remove the leg/caster. Place blocking
underneath the unit. Do not work underneath a raised
unit without proper blocking. Do not lift the unit more
than necessary to remove the leg/caster. Lifting the unit
too far can make the unit unstable.
,
Caution
All single-section units require that the swivel casters be
mounted on the front and rigid casters be mounted on
the rear.