28 Part Number: 9294997A 09/21
Operation Section 3
Adaptive Defrost
The temperature control monitors the evaporator
temperature and will turn off the compressor and condenser
fan motor when needed to allow accumulated frost on the
evaporator to clear. Additionally the freezer evaporator fan
will turn off and the defrost heater will switch on to warm
the coil. During this defrost cycle, the control will display
a defrost icon. After the defrost cycle is complete, the
temperature control will return to a normal cooling cycle,
but the defrost icon will continue on the display until the
evaporator returns to normal cooling temperatures (up to 30
minutes). The freezer evaporator fan motor will not switch
on until the evaporator reaches -5°F (-21°C) or two minutes
AFTER the compressor and condenser fan motor have begun
operating.
The temperature control monitors evaporator temperature
and compressor run time to determine the proper time for
a positive defrost cycle. A defrost cycle can occur as often as
every 60 minutes under extremely heavy usage. It can last
a minimum of 2 minutes in a refrigerator or 6 minutes in a
freezer. The compressor will remain off until the evaporator
coil temperature exceeds:
• 41°F (5°C) or the controller reaches a time limit of 75
minutes on a refrigerated unit.
• 55°F (13°C) or the controller reaches a time limit of 35
minutes on a freezer.
Time of Day Defrost
• Selecting Time of Day Defrost activates this defrost mode.
• Time of Day Defrost requires defrost times to be set up.
Configuration Screen\Defrost Type\Time of Day Defrost
• Six defrost times are allowed.
• A blank hour and minutes will be an inactive time.
• If no defrost times are assigned, no defrost will occur.
• Increase and decrease the defrost time settings using the
up and down arrows.
• Hours 1 through 12 will be available if a 12 hour clock
format has been selected on the Time/Date page. The
AM/PM icon will allow you to switch between the two.
• Hours 1 through 23 will be available if a 24 hour clock
format has been selected on the Time/Date page.
• Minutes can be set 00 through 59.
Set Box Temperature
Configuration Screen\Set Box Temperature
Screen For Dual Temperature Cabinet Shown
• Access to this page requires the manager password.
• Increase and decrease the cabinet temperature set point
using the up and down arrows.
• Set point can only be adjusted within the set point limits.
• Refrigeration factory setting is 35.6°F, set point limits are
30°F and 60°F.
• Freezer factory setting is -1.4°F, set point limits are -5°F
and 36°F.
• Heated cabinet factory setting is 165°F, set point limits
are 120°F and 200°F.