Dantherm HCV 700 handleiding

60 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 11 van 60
11
USER MANUAL
Maintenance and care: Inspection of the lter
en
Maintenance and care
Inspection of the lter
Preventive maintenance is necessary at regular intervals if the unit is to operate eciently
and optimally without unintended stoppages, and to ensure the expected service life of at
least 10 years.
It is important to notice that intervals between lter maintenance can vary according to the
specic environment, and that moving parts are wearing parts, and will need replacement
when worn.
The factory warranty only applies if it can be documented that regular preventive main-
tenance has been carried out as prescribed. The documentation can be a written logbook
containing a company stamp or equivalent.
Maintenance must as a minimum be carried out as shown here:
Interval Task To be carried out by:
Six
months
Check lters. Replace if necessary User
Annual Change lters User
Remove the upper part of the front cover.
The unit has a built-in timer for its lter alarm (every six months as standard). The timer period
for the lter alarm can be changed via the remote control or PC Tool, or it can be reset via the
alarm button
When the timer expires, a lter alarm is triggered. A buzzer will sound and the LED “!” will light
up orange. (If the LED lights up RED, please see Troubleshooting section on pagepage 42.
Press for 5
sec.
Resets the lter alarm when the alarm is triggered
Resets the lter timer without the timer having expired.
A short beep will sound, indicating that the lter alarm has been reset correctly.
Step Action Illustration
1 Remove the lters and inspect them after
the lter alarm has been triggered.
2 Even if only one lter is dirty, we recommend
replacing both lters to avoid imbalance in
the airow through the unit.
NOTE: Replace the lters at least once a year,
regardless of whether they are dirty or an
alarm has been triggered.
3 When the lters have been replaced, the
lter alarm must be reset by briey pressing
the alarm button.
A short beep will sound, indicating that the
lter alarm has been reset correctly.
Introduction
Summary of
intervals
Preparation for
inspection
Filters - alarm and
inspection
(6 months - 1 year)

Bekijk gratis de handleiding van Dantherm HCV 700, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkDantherm
ModelHCV 700
CategorieNiet gecategoriseerd
TaalNederlands
Grootte4620 MB