Installation: Handling and set-up
Plug the room unit into a power socket.
• As standard the ACT 7 requires a fused electrical supply (UK 13A, Europe 16A) rated at
230 Volts, ~1N, 50Hz. The ACT 7 is equipped with a UK plug (CEE 7/7) as standard.
If an extension cable is used the following specications must be complied to.
Extension cable
(length)
Extension cable
(min. width)
max. 10 m 2,5mm
2
10 m and more 4,0mm
2
Improper use of cables or using insucient cable type can cause short circuit and re
hazard
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualied persons in order to avoid a hazard.
• Use extension cable with the right specication (be aware that most domestic propri-
etary extension cables are 1,5mm
2
- this is not sucient)
• If the cable is on a ‘cable drum’ then ensure that it is completely unwound in accordance
with the manufacturer’s instructions
Electrical supply
War ning
Caution
CAUTION