≤45°
e30bk595.10
Illustration 6: Lifting NXN/NXI Units
Move the unit to the place needed.
The power unit can temporarily rest on the cooling fan assembly.
N O T I C E
RISK OF DAMAGE TO THE FANS
Shocks or nonvertical forces can damage the fans.
Avoid abruptly placing the power unit on the cooling fan assembly during the lifting of the unit.
After lifting the unit, check for signs of damage on the unit.
Recycle the packaging material according to local regulations.
4.5 Lifting the AC Chokes
The units are delivered either in a plywood case. To lift the units out of the case, use lifting equipment capable of handling the
weight of the units.
Find the eyebolts on the top of the unit.
Check the weights in 12.2 Weights of the AC Chokes.
AQ468246143802en-000201 / DPD0088826 | Danfoss A/S © 2023.09
Receiving the Delivery
VACON® NXP IP00 Drive Modules
Operating Guide