Diagram6B
AMP-4750 DSP and IW SUB S-100 connection schemes
6.4 Loudspeaker Connection Options
The AMP-4750 DSP is able to power a varie of
DALI PHANTOM custom install or hi-fi loudspeakers
and subwoofers. It is by default setup without any
loudspeaker or subwoofer presets installed. If
connecting loudspeakers or subwoofers that require
presets, their installation is described in Section5.3.1 of
this manual.
Each AMP-4750 DSP output channel is able to drive
a maximum of two loudspeakers or subwoofers. If two
loudspeaker or subwoofers are driven by one channel
they must be the same model. Some loudspeaker and
subwoofer connection schemes are illustrated in the
Diagram6B.
NOTE
Diagram6B shows examples of input and output
configurations. Alternative input and output
schemes can be configured via the PHANTOM
AMP CONFIGURATOR interface.
6.5 Speaker Cable Gauge
AMP-4750 DSP loudspeaker connection cable gauge
should be chosen appropriately to reflect the pe of
installation. The adjacent tables speci the appropriate
cable gauge and maximum cable length for less than
0.5dB cable loss in Lo-Z mode and less than 1.0dB cable
loss in Hi-Z mode.
Cable Gauge Table
Lo-Z installations, 0.5dB aenuation
2 Ω, 4 Ω & 8 Ω loads
Cable Cross
Section
(mm
2
)
Cable Gauge
(AWG)
Max Cable
Length
(Metres, 2 Ω
load)
Max Cable
Length
(Metres, 4 Ω
load)
Max Cable
Length
(Metres, 8 Ω
load)
0.75 ≈18 N/A 5 10
1.5 ≈16 5 10 20
2.5 ≈14 8 17 35
4.0 ≈12 14 28 55
Cable Gauge Table
70V Hi-Z installations, 1.0dB aenuation
20 loudspeakers evenly distributed
Cable Cross
Section
(mm
2
)
Cable Gauge
(AWG)
Max Cable Length
(Metres),
(1000W/channel)
Max Cable Length
(Metres),
(1200W/channel)
0.75 ≈18 25 20
1.5 ≈16 50 40
2.0 ≈14 80 60
3.5 ≈12 125 100
Cable Gauge Table
100V Hi-Z installations, 1.0dB aenuation
20 loudspeakers evenly distributed
Cable Cross
Section
(mm
2
)
Cable Gauge
(AWG)
Max Cable Length
(Metres),
(1000W/channel)
Max Cable Length
(Metres),
(1500W/channel)
0.75 ≈18 50 30
1.5 ≈16 100 60
2.0 ≈14 160 100
3.5 ≈12 250 160
6.6 GPIO Connections
If any AMP-4750 DSP GPIO functionali is
required, cables will need to be connected to the
supplied GPIO connector. Connecting cables to
the GPIO connector is illustrated in Diagram6F.
6.7 Network Connections
The AMP-4750 DSP amplifier is a TCP/IP
network connected device that is configured via
a web page based interface. Wired (Ethernet)
and wireless (WiFi) connection options are
available. Connecting the AMP-4750 DSP
amplifier to a TCP/IP network is described in
Section5 of this manual.
NOTE
The supplied “Euro Block” loudspeaker
connectors can accept up to 2.5mm
2
/ 14 gauge
loudspeaker wire.
The exclamation point printed next to the output terminals of the amplifier is, in addition to the
CLASS 2 WIRING” text, intended to alert users to the risk of hazardous voltages. Output
connectors that could pose a risk are marked with the exclamation point. Do not touch the output
terminals while the amplifier is switched on. Make all connections with the amplifier switched o.
PROCESSOR /
AV RECEIVER
PROCESSOR /
AV RECEIVER
PHANTOM CI
AMP-4750 DSP
PHANTOM CI
AMP-4750 DSP
OUTPUTS
CH1CH2CH3 CH4
OUTPUTS
CH1CH2CH3 CH4
CH2
CH4
CH1
CH3
ANALOG INPUTS
CH2
CH4
CH1
CH3
ANALOG INPUTS
Sub (LFE)
Centre
Right
Surr. L
Surr. R
Surr. Back L
Surr. Back R
ANALOG
OUTPUTS
ANALOG
OUTPUTS
FRONT LEFT
SURROUND
LEFT
SURROUND
RIGHT
FRONT RIGHT
LFE SUBWOOFER 1
LFE SUBWOOFER 2
(OPTIONAL)
CENTRE
SURROUND
BACK LEFT
SURROUND
BACK RIGHT
Left, Centre, Right + Subwoofer (LFE) Surround channels
14 15

Bekijk gratis de handleiding van Dali Phantom CI AMP-4750 DSP, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkDali
ModelPhantom CI AMP-4750 DSP
CategorieNiet gecategoriseerd
TaalNederlands
Grootte3633 MB