2.2 Insert the drainage joint to the hole at the bottom of the outdoor unit.
2.3 Connect the drainage hose to the joint and make the connection well enough.
Step3: Fix Outdoor Unit
3.1 According to the outdoor unit installation dimensions to mark the installation position for expansion bolts .
3.2 Drill holes and clean the concrete dust and place the bolts .
3.3 If applicable install 4 rubber blankets on the hole before place the outdoor unit(Option).This will reduce
vibrations and noise.
3.4 Place the outdoor unit base on the bolts and pre-drilled holes.
3.5 Use wrench to fix the outdoor unit firmly with bolts.
ā— Note:
The outdoor unit can be fixed on a wall-mounting bracket. Follow the
instruction of the wall-mounting bracket to fix the wall-mounting bracket on
the wall, and then fasten the outdoor unit on it and keep it horizontal.
The wall-mounting bracket must be able to support at least
4 times of the
weight of outdoor unit.
Step4:Install Writing(
The following are 2 zone system and 5 zone system,and other analogies
)
4.1 Use a phillips screwdriver to unscrew wiring cover, grasp and press it down gently to take it down.
4.2 Unscrew the cable clamp and take it down.
4.3 According to the wiring diagram pasted inside the wiring cover, connect the connecting wires to the
corresponding terminals, and ensure all connections are firmly and securely.
4.4 Reinstall the cable clamp and wiring cover.
When connecting the wires of indoor and outdoor units, the power should be cut off.
Note: Install the cable, please refer to fron t page "Cable Connection Between IDU To ODU".
Step5:Connecting Refregerant Pipe
5.1 Unscrews the valve cover, grasp and press it down gently to take it down (if the valve cover is applicable).
5.2 Remove the protective caps from the end of valves.
5.3 Take off the plastic cover in the pipe ports and check whether there is any sundry on the port of the
connecting pipe and make ensure the port is clean.
5.4 After aligning the center, rotate the flare nut of the connecting pipe to tighten the nut as tightly as possible