Air Conditioner Service Manual
12
In heating operation, if air conditioner turn off, the indoor fan motor will run most for 30 seconds
since the stop of compressor.
2) Auto fan control (heating)
In heating mode (include in “feel” mode) , fan speed is determined by δt as the following:
(3) 4-way valve control
In heating mode, 4-way valve will power on ahead of compressor for 8 seconds, and cut off for 2
minutes later than compressor. 4-way valve will not power off unless the machine to be switched off,
mode changed or on the process of defrosting.
(4) Outdoor fan motor control
In heating mode, the outdoor fan motor will power on ahead of compressor 5 seconds, and cut off
for 30seconds later than compressor.
(5) Defrosting
Defrosting is controlled by the microprocessor.
When the unit operate 30 minutes accumulated and the compressor operation more than 3 minutes
continuously, one of the following conditions is satisfied, unit comes into defrosting:
a.
When FrostDeg -5, and OPT -5, the .2 times defrosting interval time is 45 minutes.
b.
When -10 FrostDeg < -5, and OPT < FrostDeg , the .2 times defrosting interval time is 45
minutes.
c.
When -13 FrostDeg < -10, and OPT < FrostDeg , the .2 times defrosting interval time is 45
minutes.
d.
When -15 FrostDeg < -13, and OPT < FrostDeg , the .2 times defrosting interval time is 65
RT-ST
δt come down
δt come up
4.0
3.0
1.5
1.0
High fan
Min fan
Low fan
Indoor pipe Temperature
3S
5S
30S
120S
ON
OFF
ON
ON
OFF
OFF
4-WAY valve
Outdoor fan motor
Compressor
5S
30S
ON
ON
OFF
OFF
Outdoor fan motor
Compressor
33
Breeze
Temperature up
Temperature down
Setting
Low fan
Stop
37
33
25
25
20

Bekijk gratis de handleiding van Daizuki DXFMT-3624-4Z, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.