P37
Cooling
setting
temperature
under auto
mode*
17°C~30°C
(63°F~86°F)
25°C
(77°F)
When the
temperature unit is
°C, cooling setting
temperature minus
heating setting
temperature ≥1°C.
When the
temperature unit is
°F, cooling setting
temperature minus
heating setting
temperature ≥2°F.
P38
Heating
setting
temperature
under auto
mode*
16°C~29°C
(61°F~84°F)
20°C
(68°F)
P43
Set priority
operation*
00: normal
operation
01: priority
operation
00
When power
supply is
insufcient, the
indoor units which
are set to priority
operation can
operate, while
other indoor units
are forced to be
turned off.