8 3P130767-4K English
Though the fan can be stopped by the setting of remote con-
troller.
Do not stop the fan in the place where no ventilation by stop-
ping the fan may cause the influence of diffusion of air which
it is dirty and moisture into another room, or the inflow from
outside the room.
(outflow such as viruses from the sickroom, or smell leakage
from the rest room, etc.)
Contact your local dealer for details.
Hot start
The remote controller will read “ ” until the hot air
starts blowing, e.g. at the start of heating operation.
3.2 SETTING THE MAIN REMOTE CONTROLLER
(Refer to figure 5)
When the system is installed as shown bellow it is neces-
sary to designate one of the remote controllers as the MAIN
remote controller.
Only the MAIN remote controller can select cooling, heating,
or automatic operation (the last only on simultaneous cool-
ing/heating systems).
The displays of SUB remote controllers show “
(changeover under control) and they automatically follow the
operation mode directed by the MAIN remote controller.
However, it is possible to changeover to program dry with SUB
remote controllers if the system is in cooling operation set by the
MAIN remote controller.
HOW TO DESIGNATE THE MAIN REMOTE CONTROLLER
Press the operation mode selector button of the current
MAIN remote controller for 4 seconds.
The display showing“ ” (changeover under
control) of all SUB remote controllers connected to the
same outdoor unit or BS unit flashes on.
” flashes when the power is first turned on.
The ventilation mode can be changed regardless of the set-
ting (MAIN or SUB).
NOTE
This unit cannot control room temperature. If the unit is con-
nected to the same system with other indoor units, set the
MAIN remote controller on the other indoor units.
Press the operation mode selector button of the controller that
you wish to designate as the MAIN remote controller. Then
designation is completed. This remote controller is designated
as the MAIN remote controller and the display showing
” (changeover under control) vanishes.
The displays of other remote controller show
” (changeover under control).
Press the operation mode selector button on the MAIN
remote controller (i.e. a remote controller which does not
display “ ”) to scroll through the modes. The
display will scroll through “ ” – “ ” (only for simulta-
neous cooling/heating systems) – “ ” – “ ”.
The display on SUB remote controllers will also change
automatically.
DETAILS AND ACTIVITY OF OPERATION
Setting the MAIN remote controller (without the
” display) to cooling/heating mode will make
SUB remote controllers (with the “ ” display) to
follow to the mode of the MAIN remote controller.
Selection of fan mode is possible, however.
Setting the MAIN remote controller (without the
” display) to fan mode will make SUB remote
controllers (with the “ ” display) any setting other
than fan mode impossible.
3.3 PROGRAMMING START AND STOP OF THE
SYSTEM WITH TIMER
3.3.1 HOW TO PROGRAM AND SET THE TIMER WITH THE
REMOTE CONTROLLER “BRC1D527”
(Refer to figure 6)
The controller is equipped with a schedule timer that
enables the user to operate the installation automatically;
setting the clock and day of the week is required to be able
to use the schedule timer.
To set up clock, refer to the operation manual of the remote
controller.
(Cooling/heating selection operation systems)
When multiple indoor units
or this unit are connected to
a single outdoor unit.
One of these remote controllers can be
designated as the MAIN remote controller.
Indoor unit
Heat Reclaim Ventilator
-with DX coil-
(Simultaneous cooling/heating systems)
If multiple indoor units or many
of this unit are connected to
outdoor unit via BS unit.
BS unit
Heat Reclaim Ventilator
-with DX coil-
One of these remote controllers can be
designated as the MAIN remote controller.
Indoor unit
BS unit:
This is the unit which
selects cooling and
heating.
1
2
3
01_EN_3P130767-4K.fm 8 ページ 013年3月21日 木曜日 午前11時50分