RMXS112~160E8V1B
Super Multi Plus System air conditioner
4PW40721-1A
Installation manual
5
5.1. Installation method for prevention of falling
over
If it is necessary to prevent the unit from falling over, install as shown
in the figure.
■ prepare all 4 wires as indicated in the drawing
■ unscrew the top plate at the 4 locations indicated A and B
■ put the screws through the nooses and screw them back tight
5.2. Method for removing transportation stay
The yellow transportation stay installed over the compressor leg for
protecting the unit during transport must be removed. Proceed as
shown in figure 3 and described below.
1 Slightly loosen each fixing nut (B).
2 Remove the transportation stay (C) as shown in figure 3.
3 Tighten the fixing nut (B) again.
5.3. Method for installing drain piping
Depending on installation site, it may be required to install drain plug
for drainage (supplied with the unit).
In cold areas, do not use a drain hose with the outdoor unit.
Otherwise, drain water may freeze, impairing the heating
performance.
1 See figure 12 for installation of the drain plug.
2 Connect a field supplied vinyl hose (internal diameter of 25 mm)
to the drain socket (A).
If the hose is too long and hangs down, fix it carefully to prevent
kinks.
6. INSTALLATION SERVICING SPACE
■ The connection piping outlet direction in the installation shown in
figure 4 is frontward or downward. The unit of numeric values is
mm.
■ When routing the piping backward, secure space of ≥250 mm on
the right side of the unit.
(A) In case of non-stacked installation (See figure 4)
(B) In case of stacked installation
1. In case obstacles exist in front of the outlet side.
2. In case obstacles exist in front of the air inlet.
(C) In case of multiple-row installation (for roof top use, etc.)
1. In case of installing one unit per row.
A Location of the 2 fixation holes on the front side of the unit
B Location of the 2 fixation holes on the rear side of the unit
C Wires: field supply
A Compressor
B Fixing nut
C Transportation stay
CAUTION
If the unit is operated with the transportation stay attached,
abnormal vibration or noise may be generated.
A Drain socket
B Drain cap
C Drain receiver
D Insulation tape
E Drain stop
NOTE
If drain holes of the outdoor unit are covered by a
mounting base or by floor surface, raise the unit in
order to provide a free space of more than 100 mm
under the outdoor unit. (See figure 12)
C
B
AA
Suction side obstacle
1 In these cases, close the
bottom of the installation
frame to prevent the
discharged air from
being bypassed
Discharge side obstacle
Left side obstacle
2 In these cases, only
2 units can be installed.
Right side obstacle
3 In these cases, no
restriction of height L1.
Top side obstacle
This situation is not
allowed
✓ Obstacle is present
NOTE
■ Do not stack more than one unit.
■ About 100 mm is required as the dimension
for laying the upper outdoor unit's drain pipe.
■ Get the portion A sealed so that air from the
outlet does not bypass.
≥1
000
100
A
≥300
100
A
≥1
000
≥2
00
≥2
000
≥100