Daikin RXYSA8AMY1B handleiding
Handleiding
Je bekijkt pagina 5 van 56

1 About this document
Installation and operation manual
5
RXYSA8~12AMY1B
VRV 5-S system air conditioner
4P752781-1C – 2024.10
16 Charging refrigerant 35
16.1 Precautions when charging refrigerant...................................... 35
16.2 To determine the additional refrigerant amount......................... 36
16.3 To charge refrigerant ................................................................. 36
16.4 Error codes when charging refrigerant ...................................... 37
16.5 To fix the fluorinated greenhouse gases label........................... 37
16.6 To check refrigerant piping joints for leaks after charging
refrigerant .................................................................................. 38
17 Electrical installation 38
17.1 About electrical compliance....................................................... 38
17.2 Specifications of standard wiring components .......................... 38
17.3 Connecting the electrical wiring................................................. 38
17.4 To connect the electrical wiring to the outdoor unit ................... 39
17.5 To connect the external outputs ................................................ 40
17.6 To connect the cool/heat selector switch option........................ 41
17.7 To check the insulation resistance of the compressor............... 41
18 Configuration 41
18.1 Making field settings .................................................................. 41
18.1.1 About making field settings......................................... 41
18.1.2 Field setting components............................................ 42
18.1.3 To access mode 1 or 2 ............................................... 42
18.1.4 To use mode 1............................................................ 42
18.1.5 To use mode 2............................................................ 42
18.1.6 Mode 1: monitoring settings........................................ 42
18.1.7 Mode 2: field settings.................................................. 43
18.1.8 Indoor unit field setting................................................ 44
19 Commissioning 44
19.1 Precautions when commissioning ............................................. 44
19.2 Checklist before commissioning ................................................ 44
19.3 Checklist during commissioning ................................................ 45
19.4 About the SV unit test run.......................................................... 45
19.5 About the system test run.......................................................... 45
19.5.1 To perform a test run .................................................. 45
19.5.2 Correcting after abnormal completion of the test run.. 46
19.6 To perform a SV/indoor unit connection check.......................... 46
20 Hand-over to the user 46
21 Maintenance and service 47
21.1 Maintenance safety precautions................................................ 47
21.1.1 To prevent electrical hazards...................................... 47
21.2 Checklist for yearly maintenance of the outdoor unit................. 47
21.3 About service mode operation................................................... 47
21.3.1 To use vacuum mode ................................................. 47
21.3.2 To recover refrigerant ................................................. 47
21.3.3 Before the maintenance and service of a system with
SV unit ........................................................................ 47
21.4 SV unit maintenance and service label ..................................... 48
22 Troubleshooting 48
22.1 Solving problems based on error codes .................................... 48
22.1.1 Error codes: Overview ................................................ 48
22.2 Refrigerant leak detection system ............................................. 51
23 Disposal 52
24 Technical data 52
24.1 Service space: Outdoor unit ...................................................... 52
24.2 Piping diagram: Outdoor unit..................................................... 53
24.3 Wiring diagram: Outdoor unit..................................................... 53
1 About this document
Target audience
Authorised installers + end users
INFORMATION
This appliance is intended to be used by expert or trained
users in shops, in light industry, and on farms, or for
commercial and household use by lay persons.
Documentation set
This document is part of a documentation set. The complete set
consists of:
▪ General safety precautions:
▪ Safety instructions that you must read before installing
▪ Format: paper (in the box of the outdoor unit)
▪ Outdoor unit installation and operation manual:
▪ Installation and operation instructions
▪ Format: paper (in the box of the outdoor unit)
▪ Installer and user reference guide:
▪ Preparation of the installation, reference data,…
▪ Detailed step-by-step instructions and background information
for basic and advanced usage
▪ Format: Digital files on https://www.daikin.eu. Use the search
function to find your model.
The latest revision of the supplied documentation is published on the
regional Daikin website and is available via your dealer.
The original instructions are written in English. All other languages
are translations of the original instructions.
2 Specific installer safety
instructions
Always observe the following safety instructions and regulations.
Installation site (see "14.1Preparing the installation
site"[427])
WARNING
Follow the service space dimensions in this manual to
install the unit correctly. See "24.1Service space: Outdoor
unit"[452].
WARNING
Tear apart and throw away plastic packaging bags so that
nobody, especially children, can play with them. Possible
consequence: suffocation.
CAUTION
Excessive refrigerant concentrations in a closed room can
lead to oxygen deficiency.
WARNING
If the appliance contains R32 refrigerant, the floor area of
the room in which the appliance is stored shall be at least
429m².
Bekijk gratis de handleiding van Daikin RXYSA8AMY1B, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Daikin |
Model | RXYSA8AMY1B |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 9612 MB |