Daikin RXYA12A7Y1B handleiding
Handleiding
Je bekijkt pagina 4 van 64

1 About this document
Installation and operation manual
4
RYMA5+RXYA8~20A7Y1B
VRV 5 heat pump
4P739915-1C – 2024.10
15.3.5 To perform vacuum drying .......................................... 34
15.3.6 To insulate the refrigerant piping ................................ 34
15.3.7 To check for leaks after charging refrigerant .............. 35
16 Charging refrigerant 35
16.1 Precautions when charging refrigerant...................................... 35
16.2 About charging refrigerant ......................................................... 36
16.3 To determine the additional refrigerant amount......................... 36
16.4 To charge refrigerant: Flow chart .............................................. 37
16.5 To charge refrigerant ................................................................. 37
16.6 Error codes when charging refrigerant ...................................... 38
16.7 Checks after charging refrigerant .............................................. 38
16.8 To fix the fluorinated greenhouse gases label........................... 38
16.9 To check refrigerant piping joints for leaks after charging
refrigerant .................................................................................. 39
17 Electrical installation 39
17.1 About electrical compliance....................................................... 39
17.2 Specifications of standard wiring components .......................... 40
17.3 Connecting the electrical wiring................................................. 40
17.4 To route and fix the interconnection wiring................................ 41
17.5 To connect the interconnection wiring ....................................... 41
17.6 To finish the interconnection wiring ........................................... 42
17.7 To route and fix the power supply ............................................. 42
17.8 To connect the power supply..................................................... 42
17.9 To connect the external outputs ................................................ 43
17.10 To check the insulation resistance of the compressor............... 43
18 Configuration 43
18.1 Making field settings .................................................................. 44
18.1.1 About making field settings ......................................... 44
18.1.2 Field setting components ............................................ 44
18.1.3 To access the field setting components...................... 44
18.1.4 To access mode 1 or 2 ............................................... 44
18.1.5 To use mode 1 ............................................................ 45
18.1.6 To use mode 2 ............................................................ 45
18.1.7 Mode 1: monitoring settings........................................ 45
18.1.8 Mode 2: field settings .................................................. 46
18.1.9 Indoor unit field setting................................................ 47
18.2 Using the leak detection function............................................... 47
18.2.1 About automatic leak detection................................... 47
18.2.2 To manually perform a leak detection......................... 48
19 Commissioning 48
19.1 Precautions when commissioning ............................................. 48
19.2 Checklist before commissioning ................................................ 48
19.3 Checklist during commissioning ................................................ 49
19.4 About the SV unit test run.......................................................... 49
19.5 About the system test run.......................................................... 49
19.5.1 To perform a test run .................................................. 49
19.5.2 Correcting after abnormal completion of the test run.. 50
19.6 To perform a SV/indoor unit connection check.......................... 50
20 Hand-over to the user 51
21 Maintenance and service 51
21.1 Maintenance safety precautions................................................ 51
21.1.1 To prevent electrical hazards...................................... 51
21.2 Checklist for yearly maintenance of the outdoor unit................. 51
21.3 About service mode operation................................................... 51
21.3.1 To use vacuum mode ................................................. 52
21.3.2 To recover refrigerant ................................................. 52
21.3.3 Before the maintenance and service of a system with
SV unit ........................................................................ 52
21.4 SV unit maintenance and service label ..................................... 52
22 Troubleshooting 52
22.1 Solving problems based on error codes .................................... 52
22.1.1 Error codes: Overview ................................................ 52
22.2 Refrigerant leak detection system ............................................. 56
23 Disposal 57
24 Technical data 57
24.1 Service space: Outdoor unit ...................................................... 57
24.2 Piping diagram: Outdoor unit..................................................... 59
24.3 Wiring diagram: Outdoor unit..................................................... 61
25 Glossary 62
1 About this document
Target audience
Authorised installers + end users
INFORMATION
This appliance is intended to be used by expert or trained
users in shops, in light industry and on farms, or for
commercial use by lay persons.
Documentation set
This document is part of a documentation set. The complete set
consists of:
▪ General safety precautions:
▪ Safety instructions that you must read before installing
▪ Format: paper (in the box of the outdoor unit)
▪ Outdoor unit installation and operation manual:
▪ Installation and operation instructions
▪ Format: paper (in the box of the outdoor unit)
▪ Installer and user reference guide:
▪ Preparation of the installation, reference data,…
▪ Detailed step-by-step instructions and background information
for basic and advanced usage
▪ Format: Digital files on https://www.daikin.eu. Use the search
function to find your model.
The latest revision of the supplied documentation is published on the
regional Daikin website and is available via your dealer.
The original instructions are written in English. All other languages
are translations of the original instructions.
2 Specific installer safety
instructions
Always observe the following safety instructions and regulations.
Installation site (see "14.1Preparing the installation
site"[426])
WARNING
Follow the service space dimensions in this manual to
install the unit correctly. See "24.1Service space: Outdoor
unit"[457].
WARNING
Tear apart and throw away plastic packaging bags so that
nobody, especially children, can play with them. Possible
consequence: suffocation.
CAUTION
Appliance NOT accessible to the general public, install it in
a secured area, protected from easy access.
This unit, both indoor and outdoor, is suitable for
installation in a commercial and light industrial
environment.