6 | Unit installation
Installer reference guide
30
RXF20~42E5V1B+ARXF20~42E5V1B
R32 split series
4P519439-21V – 2022.10
6.3.2 Precautions when mounting the outdoor unit
INFORMATION
Also read the precautions and requirements in the following chapters:
▪ General safety precautions
▪ Preparation
6.3.3 To provide the installation structure
Check the strength and level of the installation ground so that the unit will not
cause any operating vibration or noise.
Fix the unit securely by means of foundation bolts in accordance with the
foundation drawing.
Prepare 4 sets of M8 or M10 anchor bolts, nuts and washers (field supply).
20 mm
300
470
192
(mm)
192
a
a 100mm above expected level of snow
6.3.4 To install the outdoor unit
4× M8/M10