2 General safety precautions
Operation manual
5
LMCEY1A/W + LMCEY2A/W
Daikin LMC
4P753996-1 – 2024.06
CAUTION
In case there is ice formation on the
unit, do not use hot water or any
mechanical tools or objects to remove
the ice. This could cause damage and
a potential leak.
Disclaimer
Should you come into possession, legitimate or not, of the OEM
password of the installation, you are prohibited from changing any
parameters via that privileged access level. Daikin always reserves
the possibility of performing an integrity check of the factory
parameters. If these are found to have been tampered with, Daikin
is in no way liable for any resulting failure, damage or warranty
obligation.
Refrigerant
The unit is factory charged with refrigerant, no additional charging of
refrigerant is required.
DANGER
This unit uses R290 as refrigerant. Do
NOT discharge refrigerant in the
atmosphere, it must be recovered by
specialised technicians using suitable
equipment.
DANGER
Take sufficient precautions in case of
refrigerant leakage. If refrigerant gas
leaks, immediately switch off the power
supply (for each unit) and ventilate the
area. Possible risks:
▪ Carbon dioxide poisoning.
▪ Asphyxiation.
▪ Fire.
WARNING
▪ NEVER directly touch any accidental
leaking refrigerant. This could result
in severe wounds caused by frostbite.
▪ Do NOT touch the refrigerant pipes
during and immediately after
operation as the refrigerant pipes
may be hot or cold, depending on the
condition of the refrigerant flowing
through the refrigerant piping,
compressor, and other refrigerant
cycle parts. Your hands may suffer
burns or frostbite if you touch the
refrigerant pipes. To avoid injury, give
the pipes time to return to normal
temperature or, if you must touch
them, be sure to wear proper gloves.
WARNING
▪ Do NOT pierce or burn refrigerant
cycle parts.
▪ Do NOT use cleaning materials or
means to accelerate the defrosting
process other than those
recommended by the manufacturer.
▪ Be aware that the refrigerant inside
the system is odourless.
INFORMATION
R290 is denser than air, so in open air it sinks to floor level.
Electrical
DANGER: RISK OF
ELECTROCUTION
▪ Turn OFF all power supply before
removing the switch box cover,
connecting electrical wiring or
touching electrical parts.
▪ Disconnect the power supply for
more than 10minutes, and measure
the voltage at the power supply
terminals of the compressor inverter
before servicing. The voltage MUST
be less than 50VDC before you can
touch electrical components.
▪ Do NOT touch electrical components
with wet hands.
▪ Do NOT leave the unit unattended
when the service cover is removed.