8 Troubleshooting
Installation and operation manual
14
FXAA15~63AUV1B
VRV system air conditioner
3P622285-1C – 2022.02
INFORMATION
To stop the alarm of the user interface, see the reference
guide of the user interface.
8 Troubleshooting
If one of the following malfunctions occur, take the measures shown
below and contact your dealer.
WARNING
Stop operation and shut OFF the power if anything
unusual occurs (burning smells etc.).
Leaving the unit running under such circumstances may
cause breakage, electrical shock or fire. Contact your
dealer.
The system MUST be repaired by a qualified service person.
Malfunction Measure
If a safety device such as a fuse, a
circuit breaker or a residual current
device frequently actuates or the ON/
OFF switch does NOT function properly.
Turn OFF all main power
supply switches to the
unit.
If water leaks from the unit. Stop operation.
The operation switch does NOT function
properly.
Turn OFF the power
supply.
If the user interface displays .
Notify your installer and
report the error code. To
display an error code see
the reference guide of the
user interface.
If the system does NOT operate properly except for the above
mentioned cases and none of the above mentioned malfunctions is
evident, investigate the system in accordance with the following
procedures.
INFORMATION
Refer to the reference guide located on https://
www.daikin.eu for more troubleshooting tips. Use the
search function to find your model.
If after checking all above items, it is impossible to fix the problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).
9 Relocation
Contact your dealer to remove and reinstall the entire unit. Moving
units requires technical expertise.
10 Disposal
NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation. Units
MUST be treated at a specialised treatment facility for
reuse, recycling and recovery.
For the installer
11 About the box
11.1 Indoor unit
11.1.1 To remove the accessories from the
indoor unit
8/9×, 2×1× 1× 4× 1×
cba d
1×
e f
a Installation and operation manual
b General safety precautions
c Screw pack: M4×25L (8× for FXAA15~32, 9× for
FXAA40~63), 2× M4×12L
d Tie wraps (1 large, 3 small)
e Insulation tape
f Paper pattern for installation
12 Unit installation
12.1 Preparing the installation site
Avoid installation in an environment with a lot of organic solvents
such as ink and siloxane.
WARNING
The appliance shall be stored in a room without
continuously operating ignition sources (example: open
flames, an operating gas appliance or an operating electric
heater).
12.1.1 Installation site requirements of the
indoor unit
Minimum floor area requirements
CAUTION
The total refrigerant charge in the system cannot exceed
the requirements for minimum floor area of the smallest
room that is served. For minimum floor area requirements
for indoor units, see the installation and operation manual
of the outdoor unit.
INFORMATION
The sound pressure level is less than 70dBA.
WARNING
Keep any required ventilation openings clear of
obstructions.