7 Maintenance and service
Installation and operation manual
11
FXAA15~63AUV1B
VRV system air conditioner
3P622285-1C – 2022.02
Operation Description
Hot start During hot start, the indoor unit fan will stop
operation, and the following icon will appear on the
home screen:
6.2.3 Airflow direction
When. Adjust the airflow direction as desired.
What. The system directs the airflow differently, depending on the
user selection.
CAUTION
ALWAYS use a user interface (e.g. wireless remote
control) to adjust the angle of the flap. When the flap is
swinging and you move it forcibly by hand, the
mechanism will break.
Be careful when adjusting the louvers. Inside the air
outlet, a fan is rotating at high speed.
1 Vertical airflow
The following vertical airflow directions can be set by the user
interface:
Direction Screen
Fixed position. The indoor unit
blows air in 1 of 5 fixed positions.
Swing. The indoor unit alternates
between the 5 positions.
Note: Recommended position of the horizontal blades (flaps) varies
according to the operation mode.
a
b
a Cooling operation
b Heating operation
INFORMATION
For setting procedure of the vertical airflow direction, see
the reference guide or the manual of the used user
interface.
2 Horizontal airflow
Horizontal airflow: by manually adjusting position of the vertical
blades (louvers).
To adjust the louvers (vertical blades)
1 Adjust horizontal blades using the user interface so you can
easily access the knobs on the vertical blades.
2 Hold knobs and move them down slightly.
3 Adjust left or right to the desired position while holding the
knobs.
aa
a Knobs
INFORMATION
When the unit is installed in a corner of a room, the
direction of the louvers should be facing away from the
wall. Efficiency will drop if a wall blocks the air.
6.3 To operate the system
INFORMATION
For setting of the operation mode or other settings, see the
reference guide or operation manual of the user interface.
7 Maintenance and service
7.1 Precautions for maintenance and
service
CAUTION
See "3 User safety instructions" [4 6] to acknowledge all
related safety instructions.
NOTICE
NEVER inspect or service the unit by yourself. Ask a
qualified service person to perform this work. However, as
end user, you may clean the air outlet, exterior, front panel
and air filter.
NOTICE
Maintenance MUST be done by an authorised installer or
service agent.
We recommend performing maintenance at least once a
year. However, applicable legislation might require shorter
maintenance intervals.
Following symbols may occur on the indoor unit:
Symbol Explanation
Measure the voltage at the terminals of main circuit
capacitors or electrical components before servicing.
DANGER: RISK OF ELECTROCUTION
Disconnect the power supply for more than 10 minutes,
and measure the voltage at the terminals of main circuit
capacitors or electrical components before servicing. The
voltage MUST be less than 50VDC before you can touch
electrical components. For the location of the terminals,
see the warning label for persons performing service and
maintenance.